Showing posts with label Department of Energy. Show all posts
Showing posts with label Department of Energy. Show all posts

Friday, August 3, 2012

Wattstopper Digital Dimming Room Controller



LMRC-220 Series Digital Room Controllers include one or two output(s) to control a total of up to 20 amps. Load ratings include incandescent, magnetic low voltage, forward phase compatible electronic low voltage and LED drivers, neon and cold cathode, and dimmable two-wire and threewire fluorescent ballasts. They are the foundation of a WattStopper Digital Lighting Management (DLM) system, and allow integration of occupancy sensors, daylighting controls and switches for energy-efficient lighting control.
Key Features
  • Versatile 20A controllers with line voltage relay(s) and triac-based forward phase control dimming
  • Compatible with most load types; three selectable dimming curves for each load
  • Plug to other components using Cat 5e cables with RJ45 connectors eliminating wiring errors
  • Plug n’ Go automatic configuration for quick startup
  • Store load preset level and 16 scene preset levels for each load
  • Facilitate energy saving dimming control strategies including automatic daylight harvesting

WS Link

Wednesday, July 25, 2012

Load Shedding Control by Wattstopper

This is a good white paper by Wattstopper.  Let me know if you have any questions.
Shad Asebrook
Sesco Lighting
615-830-1655 

Link to Wattstopper PDF

Solutions for Load SheddingWith energy alerts on the rise and demand charges increasing, load shedding has become an important lighting control strategy. Because many lighting loads are non-critical, they are prime candidates for load shedding along with other non-critical building loads.

Daylighting Controls
Load shedding with daylighting controls is a natural, automatic process. Because high energy demand often occurs at the same time daylighting potential is the greatest, the natural consequence of using daylighting controls will be to reduce lighting as the level of daylight increases and becomes adequate to replace artificial lighting sources.

With continuous dimming products, such as The Watt Stopper’’s LightSaver LCD control, users can define the minimum light level they want to maintain throughout the course of a day, and the dim- ming controls will adjust artificial lighting based on this setpoint and the available daylight contribu- tion. When daylight is adequate, lights will be dimmed and when daylight diminishes, artificial light levels are raised. The multi-zone option of the LCD enables the use of independent dimming controls in different areas of a building space, such as an open office area, where daylight levels may differ. One lighting zone, nearer to windows or skylights where daylight levels are higher, may dim artificial light- ing earlier in the day and to lower levels than in another lighting zone that is located further from the daylight source and receiving a smaller daylight contribution.

ON/OFF switching controls, such as The Watt Stopper’’s LightSaver LCO control, are also effective load shedding tools. Compatible with all lamp types, ON/OFF controls turn lights off when the daylight contribution reaches a user-defined level. Multi-zone controls enable bi-level, or stepped dimming, which can be particularly effective as a load shedding strategy. Most commonly, individual lamps with- in a multi-lamp fixture will be grouped into different zones; the inner lamps in three-lamp fixtures in one zone and the outer two lamps in a separate zone. The lighting in each zone is turned off once day- light levels reach a defined setpoint. Usually, the zone comprised of the inner lamps will be turned off first, reducing lighting by one-third. Later in the day, when the daylight contribution increases, the other lighting zone can be turned off. For more aggressive load shedding, the sequence can be reversed, to shed two-thirds of the lighting load earlier in the day.
The Watt Stopper Application Bulletin
Lighting Control Panels
Another effective tool for achieving load shedding is the use of lighting control panels. Panel prod- ucts perform load shedding by turning off non-critical loads during peak times.

For instance, users of The Watt StopperComplete Control panel products can employ a prepro- grammed control scenario to shed non-critical lighting loads. This could be half of the lighting in a "bi-level" controlled space. Under such a scenario, occupants are "locked out" from exercising local overrides via switches or telephone contact with the system. This control scenario can be pro- grammed to operate during daily intervals when peak loads are most likely to occur, or when a facility historically attains its highest demand. This strategy can also be invoked under energy shortage alerts.

Specialized Load Shedding Solutions
Additional automated load shedding solutions include teaming The Watt Stopper Automatic Relay Pack (ARP) with the Telephone Switch Module (TSM). Non-critical, sheddable loads are connected to one relay on the ARP-Net, while critical, non-sheddable loads are connected to the other relay. The TSM is installed on the ARP-Net network. During a power alert, a call into the TSM from the facility manager will turn off the relay with non-critical loads. The ARP’s lock-off capability ensures that once the signal from the TSM is received, lighting or other loads (i.e., HVAC, fans, etc.) immediately shut off, and that ordinary occupant overrides are not available. To restore the loads, the facility manager makes only a quick call back to the TSM and follows a sim-
ple push-button sequence.


Friday, June 22, 2012

LED Emergency Sconce

For the electrical engineering community here in Nashville and middle Tennessee, this is a great emergency LED sconce.  I have ordered a sample for TLC Engineers who asked to see the fixture and can bring it for a demonstration to anyone else who would like to see it...  thank you.

http://www.sitelighting.com/literature/g_121-EM_cut.pdf
























Shad Asebrook
Sesco Lighting
615-830-1655
SAsebrook@SescoLighting.com


  • The emergency components are completely integral to the luminaire.
  • Emergency lighting is provided for a 90 minute period in the event of power loss.
  • The 121-EM is suitable for use in ambient temperature conditions from 40°C (104°F) maximum to -10°C (14°F) minimum.
  • Available wattages include 35 watt and 50 watt.
  • In order to provide speed to market, the 121-EM is based on 121 generation 1 technology. It is available with Wide Throw (WT), Forward Throw (FT) and Medium Throw (MT) optics. Note: luminaires with MT optics include a diffuse lens.
  • 121-EM with FT and WT optics are provided with a clear glass lens for a similar outward appearance to the recently announced 121-Generation 2 sconce family.
  • 121-EM sconces with MT optics are provided with a diffuse lens. For a similar outward appearance, simply specify the DL (diffuse lens) option on 121-Generation 2 luminaires for a closer match to the 121-EM with MT optics.

Each 121-EM wall sconce includes a combination indicator light and test switch located in the door frame center, near the wall.




Tuesday, June 12, 2012

Multiple LED Downlighting

New combined Sistemalux Exterior Catalog


new exterior
2- Double ES Star LED
3- Triple ES Star LED
4- Long ES Star LED
4- Square ES Star LED
Our New Multiple Small LED is the logical continuity and extension of what has been one of Sistemalux's winning products for the past 10 years, the Recessed Multiple Line. Our LED Recessed Multiple offers great performance and the same design flexibility you and your clients have grown accustomed to.
Specifications:
  • Source Output: 860 lumens;
  • Correlated Color Temperature (CCT): 3198K;
  • Source Efficacy: 87 lumens per watts;
  • Color Rendering Index (CRI): 83+;
  • Total Delivered Output: 570 lumens;
  • L70 = 50,000Hrs;
  • Total Power Consumption (including driver): 11W;
  • Dimmable to 15% with standard incandescent dimmers;
  • Luminaire Efficacy: 51 lumens per watts;
  • 5 Year Warranty.
Great offering from Sistemalux/Iguzzini.  Let me know if you would like to see a sample.
-Shad Asebrook, Sesco Lighting in Nashville

Tuesday, February 14, 2012

Lifetime Comparisons: Fluorescents vs. LED Lighting

Here is a link and an overview of an article written by Jim Benya for Cree Lighting.  A good paper for electrical engineers and architects. 


Lighting Calculations in the LED Era

James R Benya, PE, FIES, FIALD

Developed for Cree LED Lighting

May 15, 2011

With Addendum May 22, 2011

Revision June 6, 2011

Final version June 30, 2011
2 Design Calculations with Solid State Lighting

Abstract
For decades, lighting calculations have been the backbone of lighting designs for almost all lighting applications, indoors and out. Good practice in illuminating engineering dictates that the designer uses photometric data that is adjusted to meet the conditions of the intended application by accounting for temperature, dirt, and variations of components. With LED lighting systems, the photometric test method ("absolute photometry") differs from conventional source lighting ("relative photometry"). In order to properly predict the performance of an LED lighting system and to compare results to competing conventional lighting systems, designers must be particularly careful to use appropriate factors in addition to properly using the two different photometric data formats. A discussion of each of the factors and examples of comparative calculations are provided.

Monday, January 30, 2012

Lumen Energy

I am meeting with Lumen Energy this morning.  From their site:

Lumen Energy offers a comprehensive suite of enterprise-level energy management solutions. Headquartered in Boulder, Colorado, one of the world's most sustainability-oriented, tech savvy communities, we deliver innovative solutions to our global clients that solve their most pressing energy concerns.

From daily utility invoice management, monitoring, and optimized controls, to long-term carbon management and capital planning, our solutions drive profitability, manage risk, and advance broader sustainability goals.

Lumen Energy's Strategic Alliance Partnership with HVS Global Hospitality Services provides us with deep hospitality industry expertise and intimate analytical insight into the world's most dynamic hospitality markets.

http://www.lumenenergy.net/

Utility Data Management
Real-Time Telemetry
Dynamic HVAC & Lighting Controls

Thursday, January 12, 2012

Friday, December 30, 2011

Lumewave, Wireless Lighting Control

Wireless Street Lighting Controls

Lumewave's wireless, remote control and monitoring of street lights can save energy, enhance public safety, reduce light pollution, reduce maintenance costs, provide valuable M&V information, and fixture health reporting to municipalities, states and other users. They can be used with LED, Induction, Plasma, eHID lighting, and standard HID. However, because of certain limitations with older HID technology, Lumewave can still be used with those systems, but much functionality is lost.
A centralized command system can send astronomic time based instructions to individual or groups of street lighting to reduce energy consumption, when and where possible, during night time hours.
Demand responsive and adaptive, lighting can be dropped to lower levels through user selected, multi-level dimming scenarios, or based on input from traffic monitors or other systems and sensors.  Revenue grade power metering through the use of Smart Meter chips is standard.
Signaling for location identification of Call Button activation or 911 calls, designating evacuation routes, detours and other emergency uses are standard capabilities with Lumewave controls.
Additional public safety uses can include the ability for police or other emergency vehicles to interface through their onboard computers and raise light levels from nearby streetlights even higher than normal to aid in visibility for investigation, medical administration and incident clean up.
Lumewave's Gateway and software allow users to communicate with over a million system devices if a customer's network was that large. Standard units provide a 5 mile range to devices when mounted on poles twenty feet or higher.

Friday, December 16, 2011

HE Williams Lighting, New Pendants for Open Office Lighting



Williams introduces the AB suspended architectural series featuring three baffle profiles, 2, 3, or 4-lamp T5 or T8 cross-sections, plus side perforation and divider options for added visual interest and glare control. The versatile AB Series' rectangular or curved blade design will complement a variety of architectural applications. 



Features:
  • Baffles add visual interest while reducing glare.
  • Side lamping delivers direct/indirect illumination.
  • Optional perforated side panels add contrast and subtle glow.
  • Divider option on three-lamp cross-section provides glare control.
  • Continuous row mounting available with self-aligning joining method to ensure straight rows.
  • This fixture is proudly made in the USA.
Specifications:
  • Housing – 22-gauge die-formed C.R.S. with 20-gauge die-formed C.R.S. end plates.
  • Baffle – 22-gauge steel/aluminum construction, 2” O.C.
  • Finish – Textured matte white polyester TGIC powder coat bonded to phosphate-free, multi-stage pretreated metal. All parts painted after fabrication to facilitate installation, increase efficiency, and inhibit corrosion.
  • Electrical – Electronic ballast standard, instant start T8, program start T5, rated Class P.
  • Mounting – Suspended. 1/16” dia. x 24” adjustable steel aircraft cable and mounting hardware for grid ceiling applications provided (standard). Surface mount available with alternate mounting accessories.
Labels – UL/CUL listed as fluorescent luminaire suitable for dry or damp locations.

Wednesday, November 16, 2011

DEPARTMENT OF ENERGY ADOPTS ASHRAE 90.1-2010

DEPARTMENT OF ENERGY ADOPTS ASHRAE 90.1-2010 AS THE NATIONAL REFERENCE STANDARD ON OCTOBER 19, 2011

States have until October, 2013 to update their commercial building energy codes to meet or exceed the requirements of ASHRAE 90.1-2010. This revision requires much more extensive use of lighting controls than previous versions and is anticipated to realize 18.2% more energy savings than 90.1-2007.

Click on the links below for more detailed information regarding these changes.

Sales 411 – ASHRAE 90.1-2010 vs 2007 

Brochure -
 Download the NEW CodeSmart Brochure
Click on the link for detailed information on the code status and implementation in your state.
http://bcap-ocean.org/code-status-commercial